Buffer Tank
50 L – 5,000 L50 L – 5,000 L. Buffer tank providing buffer volume in heating circuits.
- Max. Hot Water
- Maks. 90 °C
- Test Pressure
- 13 Bar
- Working Pressure
- 10 Bar
- 25+ years experience
- 7,000 m² production
- TSE & ISO certified
Overview
A buffer tank temporarily stores water between the heat source and the installation in a heating system. It collects hot water from a heat pump or solid-fuel boiler and delivers it to the circuit in a balanced way. Omega buffer tanks are made in 14 sizes from 50 to 5,000 liters, high-insulated, at our facility in İzmir Kemalpaşa with CE, ISO 9001, ISO 14001, ISO 45001 and TSE certificates.
A buffer tank prevents the heat source from switching on and off too frequently (short cycling), stabilizing the system and improving efficiency. This matters especially in heat pump and solid-fuel boiler systems, which may otherwise cycle constantly as demand changes. The buffer tank breaks this cycle for steadier operation.
Key Features
- Prevents short cycling (frequent on/off)
- Improves efficiency and extends equipment life
- Stores surplus heat and delivers it in a balanced way
- Hydraulically separates circuits (underfloor, radiators)
- High insulation for low heat loss
- Suitable for heat pump and solid-fuel boiler systems
Operating Values
Specifications Table
| Volume (L) | 50L | 100L | 160L | 200L | 300L | 500L | 800L | 1000L | 1500L | 2000L | 2500L | 3000L | 4000L | 5000L |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Diameter A (mm) | 450 | 450 | 550 | 550 | 650 | 750 | 850 | 950 | 1200 | 1200 | 1380 | 1380 | 1450 | 1650 |
| Height H (mm) | 700 | 1150 | 1150 | 1380 | 1650 | 1650 | 1700 | 2100 | 2000 | 2300 | 2300 | 2400 | 2850 | 2850 |
| Dry Weight (kg) | 24 | 36 | 50 | 60 | 93 | 140 | 195 | 212 | 360 | 510 | 575 | 680 | 780 | 900 |
| Insulation Type | PU | PU | PU | PU | PU | PU | PU | Sünger | Sünger | Sünger | Sünger | Sünger | Sünger | Sünger |
| Insulation Thickness (mm) | 50 | 50 | 50 | 50 | 50 | 50 | 50 | 50 | 50 | 50 | 50 | 50 | 50 | 50 |
| Footprint (m³) | 0,18 | 0,25 | 0,37 | 0,45 | 0,87 | 1,02 | 1,3 | 1,94 | 2,88 | 3,32 | 4,70 | 5,06 | 6,00 | 7,75 |
| Jacket | SAC | SAC | Vinlex | Vinlex | Vinlex | Vinlex | Vinlex | Vinlex | Vinlex | Vinlex | Vinlex | Vinlex | Vinlex | Vinlex |
50 L
- Diameter A (mm)
- 450
- Height H (mm)
- 700
- Dry Weight (kg)
- 24
- Insulation Type
- PU
- Insulation Thickness (mm)
- 50
- Footprint (m³)
- 0,18
- Jacket
- SAC
100 L
- Diameter A (mm)
- 450
- Height H (mm)
- 1150
- Dry Weight (kg)
- 36
- Insulation Type
- PU
- Insulation Thickness (mm)
- 50
- Footprint (m³)
- 0,25
- Jacket
- SAC
160 L
- Diameter A (mm)
- 550
- Height H (mm)
- 1150
- Dry Weight (kg)
- 50
- Insulation Type
- PU
- Insulation Thickness (mm)
- 50
- Footprint (m³)
- 0,37
- Jacket
- Vinlex
200 L
- Diameter A (mm)
- 550
- Height H (mm)
- 1380
- Dry Weight (kg)
- 60
- Insulation Type
- PU
- Insulation Thickness (mm)
- 50
- Footprint (m³)
- 0,45
- Jacket
- Vinlex
300 L
- Diameter A (mm)
- 650
- Height H (mm)
- 1650
- Dry Weight (kg)
- 93
- Insulation Type
- PU
- Insulation Thickness (mm)
- 50
- Footprint (m³)
- 0,87
- Jacket
- Vinlex
500 L
- Diameter A (mm)
- 750
- Height H (mm)
- 1650
- Dry Weight (kg)
- 140
- Insulation Type
- PU
- Insulation Thickness (mm)
- 50
- Footprint (m³)
- 1,02
- Jacket
- Vinlex
800 L
- Diameter A (mm)
- 850
- Height H (mm)
- 1700
- Dry Weight (kg)
- 195
- Insulation Type
- PU
- Insulation Thickness (mm)
- 50
- Footprint (m³)
- 1,3
- Jacket
- Vinlex
1000 L
- Diameter A (mm)
- 950
- Height H (mm)
- 2100
- Dry Weight (kg)
- 212
- Insulation Type
- Sünger
- Insulation Thickness (mm)
- 50
- Footprint (m³)
- 1,94
- Jacket
- Vinlex
1500 L
- Diameter A (mm)
- 1200
- Height H (mm)
- 2000
- Dry Weight (kg)
- 360
- Insulation Type
- Sünger
- Insulation Thickness (mm)
- 50
- Footprint (m³)
- 2,88
- Jacket
- Vinlex
2000 L
- Diameter A (mm)
- 1200
- Height H (mm)
- 2300
- Dry Weight (kg)
- 510
- Insulation Type
- Sünger
- Insulation Thickness (mm)
- 50
- Footprint (m³)
- 3,32
- Jacket
- Vinlex
2500 L
- Diameter A (mm)
- 1380
- Height H (mm)
- 2300
- Dry Weight (kg)
- 575
- Insulation Type
- Sünger
- Insulation Thickness (mm)
- 50
- Footprint (m³)
- 4,70
- Jacket
- Vinlex
3000 L
- Diameter A (mm)
- 1380
- Height H (mm)
- 2400
- Dry Weight (kg)
- 680
- Insulation Type
- Sünger
- Insulation Thickness (mm)
- 50
- Footprint (m³)
- 5,06
- Jacket
- Vinlex
4000 L
- Diameter A (mm)
- 1450
- Height H (mm)
- 2850
- Dry Weight (kg)
- 780
- Insulation Type
- Sünger
- Insulation Thickness (mm)
- 50
- Footprint (m³)
- 6,00
- Jacket
- Vinlex
5000 L
- Diameter A (mm)
- 1650
- Height H (mm)
- 2850
- Dry Weight (kg)
- 900
- Insulation Type
- Sünger
- Insulation Thickness (mm)
- 50
- Footprint (m³)
- 7,75
- Jacket
- Vinlex
Technical Drawing
Refer to the catalog technical table for connection and dimension codes.

Buffer Tank Prices
Buffer tank prices vary by model and capacity. As of July 2026, 100-liter models start around 10,000 TL on the market, while models around 300 liters can reach about 30,000 TL. Larger and industrial capacities are priced per project; we offer below-retail pricing on wholesale and project orders.
Prices are approximate and may change; request a quote for current and wholesale/project pricing.
Frequently Asked Questions
What is a buffer tank?
A buffer tank temporarily stores water between the heat source and the installation in a heating system. Omega buffer tanks are made in 14 sizes from 50 to 5,000 liters, high-insulated.
What does a buffer tank do?
Especially in heat pump and solid-fuel boiler systems, it prevents the heat source from switching on and off too frequently. This improves efficiency, extends equipment life, and stores surplus heat for balanced delivery.
What is the difference between a buffer tank and an accumulation tank?
A buffer tank holds the heating circuit (closed-loop) water and needs no inner coating. An accumulation tank stores domestic hot water, so it is made with enamel coating and cathodic protection. See our blog for a detailed comparison.
How is the right buffer tank capacity determined?
Buffer tank capacity depends on the heat source power and system type. For an exact size, we recommend contacting Omega Boyler with your project details.
Request a quote for this product