Double Coil Water Heater
160 L – 5,000 L160 L – 5,000 L. Double-coil water heater for combined boiler + solar panel installations.
- Energy Class
- B
- Max. Coil Temperature
- Maks. 110 °C
- Max. Hot Water
- Maks. 90 °C
- Test Pressure
- 13 Bar
- 25+ years experience
- 7,000 m² production
- TSE & ISO certified
Overview
A double-coil water heater has two separate coils (heat exchangers), so it can connect to two different heat sources at once. Omega double-coil water heaters are made from 160 to 5,000 liters, protected against corrosion with enamel inner coating and cathodic protection (anode rod), and rated energy class B. The most common use is combining a solar collector with a combi or boiler in a single tank.
The purpose of a double-coil water heater is to combine two heat sources in one tank for uninterrupted domestic hot water. In a typical setup the lower coil connects to the solar collector and the upper coil to the combi or boiler. When the sun provides enough heat the water is heated by solar; when it falls short, the combi steps in to bring the water to the target temperature.
Key Features
- Operates with two heat sources (e.g. solar + boiler)
- Wider coil surface for higher efficiency
- Practical, economical, modern design
- High-quality, certified materials
- Enamel inner coating
- Cathodic protection (anode rod)
- Thermometer included
- Long-lasting and durable
Operating Values
Specifications Table
| Volume (L) | 160L | 200L | 300L | 500L | 800L | 1000L | 1500L | 2000L | 2500L | 3000L | 4000L | 5000L |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Insulation Type | PU | PU | PU | PU | PU | PU | Sünger | Sünger | Sünger | Sünger | Sünger | Sünger |
| Insulation Thickness (mm) | 50 | 50 | 50 | 50 | 50 | 50 | 50 | 50 | 50 | 50 | 50 | 50 |
| Diameter A (mm) | 550 | 550 | 650 | 750 | 850 | 950 | 1200 | 1200 | 1380 | 1380 | 1450 | 1650 |
| Height H (mm) | 1150 | 1380 | 1650 | 1650 | 1700 | 2100 | 2000 | 2300 | 2300 | 2400 | 2850 | 2850 |
| Upper Coil Surface (m²) | 0,51 | 0,6 | 1 | 1,25 | 1,35 | 2 | 2,2 | 2,97 | 2,97 | 4,53 | 4,8 | 5,65 |
| Lower Coil Surface (m²) | 0,61 | 0,95 | 1,15 | 1,85 | 2 | 2,83 | 2,97 | 4,25 | 4,53 | 5,6 | 5,95 | 6,8 |
| Dry Weight (kg) | 64 | 82 | 131 | 175 | 228 | 304 | 492 | 643 | 735 | 818 | 1014 | 1210 |
| Footprint (m³) | 0,37 | 0,45 | 0,87 | 1,02 | 1,30 | 1,94 | 2,88 | 3,32 | 4,70 | 5,06 | 6,00 | 7,75 |
| Jacket | Vinlex | Vinlex | Vinlex | Vinlex | Vinlex | Vinlex | Vinlex | Vinlex | Vinlex | Vinlex | Vinlex | Vinlex |
160 L
- Insulation Type
- PU
- Insulation Thickness (mm)
- 50
- Diameter A (mm)
- 550
- Height H (mm)
- 1150
- Upper Coil Surface (m²)
- 0,51
- Lower Coil Surface (m²)
- 0,61
- Dry Weight (kg)
- 64
- Footprint (m³)
- 0,37
- Jacket
- Vinlex
200 L
- Insulation Type
- PU
- Insulation Thickness (mm)
- 50
- Diameter A (mm)
- 550
- Height H (mm)
- 1380
- Upper Coil Surface (m²)
- 0,6
- Lower Coil Surface (m²)
- 0,95
- Dry Weight (kg)
- 82
- Footprint (m³)
- 0,45
- Jacket
- Vinlex
300 L
- Insulation Type
- PU
- Insulation Thickness (mm)
- 50
- Diameter A (mm)
- 650
- Height H (mm)
- 1650
- Upper Coil Surface (m²)
- 1
- Lower Coil Surface (m²)
- 1,15
- Dry Weight (kg)
- 131
- Footprint (m³)
- 0,87
- Jacket
- Vinlex
500 L
- Insulation Type
- PU
- Insulation Thickness (mm)
- 50
- Diameter A (mm)
- 750
- Height H (mm)
- 1650
- Upper Coil Surface (m²)
- 1,25
- Lower Coil Surface (m²)
- 1,85
- Dry Weight (kg)
- 175
- Footprint (m³)
- 1,02
- Jacket
- Vinlex
800 L
- Insulation Type
- PU
- Insulation Thickness (mm)
- 50
- Diameter A (mm)
- 850
- Height H (mm)
- 1700
- Upper Coil Surface (m²)
- 1,35
- Lower Coil Surface (m²)
- 2
- Dry Weight (kg)
- 228
- Footprint (m³)
- 1,30
- Jacket
- Vinlex
1000 L
- Insulation Type
- PU
- Insulation Thickness (mm)
- 50
- Diameter A (mm)
- 950
- Height H (mm)
- 2100
- Upper Coil Surface (m²)
- 2
- Lower Coil Surface (m²)
- 2,83
- Dry Weight (kg)
- 304
- Footprint (m³)
- 1,94
- Jacket
- Vinlex
1500 L
- Insulation Type
- Sünger
- Insulation Thickness (mm)
- 50
- Diameter A (mm)
- 1200
- Height H (mm)
- 2000
- Upper Coil Surface (m²)
- 2,2
- Lower Coil Surface (m²)
- 2,97
- Dry Weight (kg)
- 492
- Footprint (m³)
- 2,88
- Jacket
- Vinlex
2000 L
- Insulation Type
- Sünger
- Insulation Thickness (mm)
- 50
- Diameter A (mm)
- 1200
- Height H (mm)
- 2300
- Upper Coil Surface (m²)
- 2,97
- Lower Coil Surface (m²)
- 4,25
- Dry Weight (kg)
- 643
- Footprint (m³)
- 3,32
- Jacket
- Vinlex
2500 L
- Insulation Type
- Sünger
- Insulation Thickness (mm)
- 50
- Diameter A (mm)
- 1380
- Height H (mm)
- 2300
- Upper Coil Surface (m²)
- 2,97
- Lower Coil Surface (m²)
- 4,53
- Dry Weight (kg)
- 735
- Footprint (m³)
- 4,70
- Jacket
- Vinlex
3000 L
- Insulation Type
- Sünger
- Insulation Thickness (mm)
- 50
- Diameter A (mm)
- 1380
- Height H (mm)
- 2400
- Upper Coil Surface (m²)
- 4,53
- Lower Coil Surface (m²)
- 5,6
- Dry Weight (kg)
- 818
- Footprint (m³)
- 5,06
- Jacket
- Vinlex
4000 L
- Insulation Type
- Sünger
- Insulation Thickness (mm)
- 50
- Diameter A (mm)
- 1450
- Height H (mm)
- 2850
- Upper Coil Surface (m²)
- 4,8
- Lower Coil Surface (m²)
- 5,95
- Dry Weight (kg)
- 1014
- Footprint (m³)
- 6,00
- Jacket
- Vinlex
5000 L
- Insulation Type
- Sünger
- Insulation Thickness (mm)
- 50
- Diameter A (mm)
- 1650
- Height H (mm)
- 2850
- Upper Coil Surface (m²)
- 5,65
- Lower Coil Surface (m²)
- 6,8
- Dry Weight (kg)
- 1210
- Footprint (m³)
- 7,75
- Jacket
- Vinlex
Technical Drawing
Refer to the catalog technical table for connection and dimension codes.

Double Coil Water Heater Prices
Double-coil water heater prices vary by capacity. As of July 2026, based on retail references on n11, 160-liter models start around 21,000 TL and 1,000-liter models can reach about 73,500 TL. Large and industrial projects are priced per project; we offer below-retail pricing on wholesale and project orders.
Prices are approximate and may change; request a quote for current and wholesale/project pricing.
Frequently Asked Questions
What is a double-coil water heater?
A double-coil water heater connects to two heat sources at once thanks to two separate coils (heat exchangers). Made from 160 to 5,000 liters, with enamel inner coating, cathodic protection and energy class B.
What does a double-coil water heater do and where is it used?
It combines a solar collector with a combi or boiler in one tank for uninterrupted hot water: solar when available, combi when not. Used in homes and villas with solar plus combi, in apartments and complexes on central systems, and in hotels and facilities needing high capacity.
What is the difference between a double-coil and a single-coil water heater?
A single-coil unit connects one heat source; a double-coil unit connects two (for example solar and combi) to the same tank for combined use. Projects planning to add solar now or later prefer double-coil.
How is a double-coil water heater connected?
The lower coil usually connects to the solar collector circuit and the upper coil to the combi or boiler circuit. The solar collector raises the water temperature first, and where it falls short the upper coil brings the water to the target temperature. Exact connection points and pipe diameters vary by capacity and are confirmed per project with our technical team.
Request a quote for this product
Let our engineering team recommend the right capacity and configuration.