Removable Copper Double Coil Water Heater
300 L – 5,000 L300 L – 5,000 L. Removable upper + lower copper coils; two heat sources and easy maintenance.
- Max. Coil Temperature
- Maks. 110 °C
- Max. Hot Water
- Maks. 90 °C
- Test Pressure
- 13 Bar
- Working Pressure
- 10 Bar
- 25+ years experience
- 7,000 m² production
- TSE & ISO certified
Overview
A removable copper double-coil water heater is a double-coil domestic hot water tank whose upper and lower copper coils can both be taken out for maintenance. Made from 300 to 5,000 liters, protected with enamel inner coating and cathodic protection, it connects to two heat sources at once (for example solar + boiler or heat pump + boiler).
While the two coils combine two heat sources, their removability is a major advantage in hard-water and heavy-use facilities: both coils can be periodically removed and cleaned to preserve heat-transfer efficiency and service life. It is designed for high-capacity, continuously operating facilities.
Key Features
- Removable upper + lower copper coils
- Operates with two heat sources
- Practical, economical, modern design
- High-quality, certified materials
- Enamel inner coating
- Cathodic protection (anode rod)
- Thermometer included
- Long-lasting and durable
Operating Values
Specifications Table
| Volume (L) | 300L | 500L | 800L | 1000L | 1500L | 2000L | 2500L | 3000L | 4000L | 5000L |
|---|---|---|---|---|---|---|---|---|---|---|
| Diameter A (mm) | 650 | 750 | 850 | 950 | 1200 | 1200 | 1380 | 1380 | 1450 | 1650 |
| Height H (mm) | 1650 | 1650 | 1700 | 2100 | 2000 | 2300 | 2300 | 2400 | 2850 | 2850 |
| Upper Copper Coil (m²) | 0,5 | 0,7 | 1,8 | 2,1 | 2,8 | 2,8 | 3,2 | 3,2 | 3,6 | 4,5 |
| Lower Copper Coil (m²) | 0,9 | 1,2 | 3,3 | 3,9 | 5 | 5 | 5,8 | 5,8 | 6,5 | 8 |
| Dry Weight (kg) | 130 | 180 | 240 | 265 | 415 | 565 | 635 | 740 | 845 | 975 |
| Insulation Type | Sünger | Sünger | Sünger | Sünger | Sünger | Sünger | Sünger | Sünger | Sünger | Sünger |
| Insulation Thickness (mm) | 50 | 50 | 50 | 50 | 50 | 50 | 50 | 50 | 50 | 50 |
| Footprint (m³) | 0,87 | 1,02 | 1,30 | 1,94 | 2,88 | 3,32 | 4,70 | 5,06 | 6,00 | 7,75 |
| Jacket | Vinlex | Vinlex | Vinlex | Vinlex | Vinlex | Vinlex | Vinlex | Vinlex | Vinlex | Vinlex |
300 L
- Diameter A (mm)
- 650
- Height H (mm)
- 1650
- Upper Copper Coil (m²)
- 0,5
- Lower Copper Coil (m²)
- 0,9
- Dry Weight (kg)
- 130
- Insulation Type
- Sünger
- Insulation Thickness (mm)
- 50
- Footprint (m³)
- 0,87
- Jacket
- Vinlex
500 L
- Diameter A (mm)
- 750
- Height H (mm)
- 1650
- Upper Copper Coil (m²)
- 0,7
- Lower Copper Coil (m²)
- 1,2
- Dry Weight (kg)
- 180
- Insulation Type
- Sünger
- Insulation Thickness (mm)
- 50
- Footprint (m³)
- 1,02
- Jacket
- Vinlex
800 L
- Diameter A (mm)
- 850
- Height H (mm)
- 1700
- Upper Copper Coil (m²)
- 1,8
- Lower Copper Coil (m²)
- 3,3
- Dry Weight (kg)
- 240
- Insulation Type
- Sünger
- Insulation Thickness (mm)
- 50
- Footprint (m³)
- 1,30
- Jacket
- Vinlex
1000 L
- Diameter A (mm)
- 950
- Height H (mm)
- 2100
- Upper Copper Coil (m²)
- 2,1
- Lower Copper Coil (m²)
- 3,9
- Dry Weight (kg)
- 265
- Insulation Type
- Sünger
- Insulation Thickness (mm)
- 50
- Footprint (m³)
- 1,94
- Jacket
- Vinlex
1500 L
- Diameter A (mm)
- 1200
- Height H (mm)
- 2000
- Upper Copper Coil (m²)
- 2,8
- Lower Copper Coil (m²)
- 5
- Dry Weight (kg)
- 415
- Insulation Type
- Sünger
- Insulation Thickness (mm)
- 50
- Footprint (m³)
- 2,88
- Jacket
- Vinlex
2000 L
- Diameter A (mm)
- 1200
- Height H (mm)
- 2300
- Upper Copper Coil (m²)
- 2,8
- Lower Copper Coil (m²)
- 5
- Dry Weight (kg)
- 565
- Insulation Type
- Sünger
- Insulation Thickness (mm)
- 50
- Footprint (m³)
- 3,32
- Jacket
- Vinlex
2500 L
- Diameter A (mm)
- 1380
- Height H (mm)
- 2300
- Upper Copper Coil (m²)
- 3,2
- Lower Copper Coil (m²)
- 5,8
- Dry Weight (kg)
- 635
- Insulation Type
- Sünger
- Insulation Thickness (mm)
- 50
- Footprint (m³)
- 4,70
- Jacket
- Vinlex
3000 L
- Diameter A (mm)
- 1380
- Height H (mm)
- 2400
- Upper Copper Coil (m²)
- 3,2
- Lower Copper Coil (m²)
- 5,8
- Dry Weight (kg)
- 740
- Insulation Type
- Sünger
- Insulation Thickness (mm)
- 50
- Footprint (m³)
- 5,06
- Jacket
- Vinlex
4000 L
- Diameter A (mm)
- 1450
- Height H (mm)
- 2850
- Upper Copper Coil (m²)
- 3,6
- Lower Copper Coil (m²)
- 6,5
- Dry Weight (kg)
- 845
- Insulation Type
- Sünger
- Insulation Thickness (mm)
- 50
- Footprint (m³)
- 6,00
- Jacket
- Vinlex
5000 L
- Diameter A (mm)
- 1650
- Height H (mm)
- 2850
- Upper Copper Coil (m²)
- 4,5
- Lower Copper Coil (m²)
- 8
- Dry Weight (kg)
- 975
- Insulation Type
- Sünger
- Insulation Thickness (mm)
- 50
- Footprint (m³)
- 7,75
- Jacket
- Vinlex
Technical Drawing
Refer to the catalog technical table for connection and dimension codes.

Removable Copper Double Coil Water Heater Prices
The removable copper double-coil water heater is a specialized product; its price is set by capacity and project specifics. We do not publish a list price, so share your capacity and needs for a fast quote. Wholesale and project orders receive advantageous pricing.
Prices are approximate and may change; request a quote for current and wholesale/project pricing.
Frequently Asked Questions
What is a removable copper double-coil water heater?
It is a double-coil water heater whose two copper coils can both be removed for maintenance. It connects to two heat sources at once and keeps its efficiency in hard water because the coils can be cleaned.
Which heat sources does it work with?
It connects to two separate heat sources at once, typically solar + boiler or heat pump + boiler. When one falls short, the other takes over.
Why is the removable coil important?
Scale from hard water builds up on the coil and reduces efficiency. Both coils can be removed and cleaned to keep efficiency and service life high over time, which is not possible with fixed coils.
Request a quote for this product
Let our engineering team recommend the right capacity and configuration.