Skip to content
Removable Copper Double Coil Water Heater — Product Image
Product Image
Water Heater

Removable Copper Double Coil Water Heater

300 L – 5,000 L

300 L – 5,000 L. Removable upper + lower copper coils; two heat sources and easy maintenance.

Max. Coil Temperature
Maks. 110 °C
Max. Hot Water
Maks. 90 °C
Test Pressure
13 Bar
Working Pressure
10 Bar
  • 25+ years experience
  • 7,000 m² production
  • TSE & ISO certified
Certifications & ComplianceCEISO 9001:2015ISO 14001:2015ISO 45001:2018TSE
01

Overview

A removable copper double-coil water heater is a double-coil domestic hot water tank whose upper and lower copper coils can both be taken out for maintenance. Made from 300 to 5,000 liters, protected with enamel inner coating and cathodic protection, it connects to two heat sources at once (for example solar + boiler or heat pump + boiler).

While the two coils combine two heat sources, their removability is a major advantage in hard-water and heavy-use facilities: both coils can be periodically removed and cleaned to preserve heat-transfer efficiency and service life. It is designed for high-capacity, continuously operating facilities.

02

Key Features

  • Removable upper + lower copper coils
  • Operates with two heat sources
  • Practical, economical, modern design
  • High-quality, certified materials
  • Enamel inner coating
  • Cathodic protection (anode rod)
  • Thermometer included
  • Long-lasting and durable
03

Operating Values

Max. Coil Temperature
Maks. 110 °C
Max. Hot Water
Maks. 90 °C
Test Pressure
13 Bar
Working Pressure
10 Bar
Inner Coating
Enamel
04

Specifications Table

300 L
Diameter A (mm)
650
Height H (mm)
1650
Upper Copper Coil (m²)
0,5
Lower Copper Coil (m²)
0,9
Dry Weight (kg)
130
Insulation Type
Sünger
Insulation Thickness (mm)
50
Footprint (m³)
0,87
Jacket
Vinlex
500 L
Diameter A (mm)
750
Height H (mm)
1650
Upper Copper Coil (m²)
0,7
Lower Copper Coil (m²)
1,2
Dry Weight (kg)
180
Insulation Type
Sünger
Insulation Thickness (mm)
50
Footprint (m³)
1,02
Jacket
Vinlex
800 L
Diameter A (mm)
850
Height H (mm)
1700
Upper Copper Coil (m²)
1,8
Lower Copper Coil (m²)
3,3
Dry Weight (kg)
240
Insulation Type
Sünger
Insulation Thickness (mm)
50
Footprint (m³)
1,30
Jacket
Vinlex
1000 L
Diameter A (mm)
950
Height H (mm)
2100
Upper Copper Coil (m²)
2,1
Lower Copper Coil (m²)
3,9
Dry Weight (kg)
265
Insulation Type
Sünger
Insulation Thickness (mm)
50
Footprint (m³)
1,94
Jacket
Vinlex
1500 L
Diameter A (mm)
1200
Height H (mm)
2000
Upper Copper Coil (m²)
2,8
Lower Copper Coil (m²)
5
Dry Weight (kg)
415
Insulation Type
Sünger
Insulation Thickness (mm)
50
Footprint (m³)
2,88
Jacket
Vinlex
2000 L
Diameter A (mm)
1200
Height H (mm)
2300
Upper Copper Coil (m²)
2,8
Lower Copper Coil (m²)
5
Dry Weight (kg)
565
Insulation Type
Sünger
Insulation Thickness (mm)
50
Footprint (m³)
3,32
Jacket
Vinlex
2500 L
Diameter A (mm)
1380
Height H (mm)
2300
Upper Copper Coil (m²)
3,2
Lower Copper Coil (m²)
5,8
Dry Weight (kg)
635
Insulation Type
Sünger
Insulation Thickness (mm)
50
Footprint (m³)
4,70
Jacket
Vinlex
3000 L
Diameter A (mm)
1380
Height H (mm)
2400
Upper Copper Coil (m²)
3,2
Lower Copper Coil (m²)
5,8
Dry Weight (kg)
740
Insulation Type
Sünger
Insulation Thickness (mm)
50
Footprint (m³)
5,06
Jacket
Vinlex
4000 L
Diameter A (mm)
1450
Height H (mm)
2850
Upper Copper Coil (m²)
3,6
Lower Copper Coil (m²)
6,5
Dry Weight (kg)
845
Insulation Type
Sünger
Insulation Thickness (mm)
50
Footprint (m³)
6,00
Jacket
Vinlex
5000 L
Diameter A (mm)
1650
Height H (mm)
2850
Upper Copper Coil (m²)
4,5
Lower Copper Coil (m²)
8
Dry Weight (kg)
975
Insulation Type
Sünger
Insulation Thickness (mm)
50
Footprint (m³)
7,75
Jacket
Vinlex
05

Technical Drawing

Refer to the catalog technical table for connection and dimension codes.

Removable Copper Double Coil Water Heater · Technical Drawing

Removable Copper Double Coil Water Heater Prices

The removable copper double-coil water heater is a specialized product; its price is set by capacity and project specifics. We do not publish a list price, so share your capacity and needs for a fast quote. Wholesale and project orders receive advantageous pricing.

Prices are approximate and may change; request a quote for current and wholesale/project pricing.

Frequently Asked Questions

What is a removable copper double-coil water heater?

It is a double-coil water heater whose two copper coils can both be removed for maintenance. It connects to two heat sources at once and keeps its efficiency in hard water because the coils can be cleaned.

Which heat sources does it work with?

It connects to two separate heat sources at once, typically solar + boiler or heat pump + boiler. When one falls short, the other takes over.

Why is the removable coil important?

Scale from hard water builds up on the coil and reduces efficiency. Both coils can be removed and cleaned to keep efficiency and service life high over time, which is not possible with fixed coils.

Request a quote for this product

Let our engineering team recommend the right capacity and configuration.

Removable Copper Double Coil Water Heater | Omega Boyler